{"product_id":"joule-cyclone-platinum-250l-twin-coil-solar-cylinder-standard-c","title":"Joule Cyclone Platinum 250L Twin Coil Solar Cylinder Standard C - TCEMVS-0250LFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 250L Twin Coil Solar Cylinder Standard C (TCEMVS-0250LFC) is a high-capacity indirect unvented hot water cylinder engineered for solar thermal and auxiliary heating systems. Designed for residential and light‑commercial installations, it combines a stainless‑steel inner cylinder with twin high‑output coils to deliver large volumes of reliable hot water while maximising heat transfer and minimising standby losses. Robust construction and dense PU foam insulation provide durability and efficient long‑term performance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eActual capacity ~247 litres for substantial hot water storage\u003c\/li\u003e\n\u003cli\u003eTwin 316L stainless‑steel coils (18 kW + 22 kW; 0.67 m² each) for efficient solar and primary heat exchange\u003c\/li\u003e\n\u003cli\u003eLDX 2101 stainless‑steel inner cylinder for corrosion resistance and longevity\u003c\/li\u003e\n\u003cli\u003eCoated mild steel outer casing with dense PU foam insulation to reduce heat loss\u003c\/li\u003e\n\u003cli\u003eSingle immersion heater port compatible with 3 kW @ 230 V immersions\u003c\/li\u003e\n\u003cli\u003eHigh pressure ratings: max mains 10 bar; operating pressure 7 bar; coil primary max 3.5 bar\u003c\/li\u003e\n\u003cli\u003eLow standing heat loss: 2.30 kWh\/24h (tested to BS EN 12897:2016)\u003c\/li\u003e\n\u003cli\u003eUnit weight: 59 kg empty, 307 kg full — solid build for fixed installations\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarger family homes or properties with high hot‑water demand\u003c\/li\u003e\n\u003cli\u003eSolar thermal systems working alongside a boiler or secondary heat source\u003c\/li\u003e\n\u003cli\u003eLight commercial settings that require substantial stored hot water\u003c\/li\u003e\n\u003cli\u003eRenovation or new‑build projects seeking durable stainless‑steel cylinders\u003c\/li\u003e\n\u003cli\u003eSystems needing dual coil flexibility (solar + backup heating)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCEMVS-0250LFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eSOLAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eIndirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (listed)\u003c\/td\u003e\n\u003ctd\u003e250 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of immersions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. heat exchangers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 2 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 2 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 max primary pressure (Bar)\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 2 max primary pressure (Bar)\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e0.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (Bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (Bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety valve temperature (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e2.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (Year)\u003c\/td\u003e\n\u003ctd\u003e1Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069262324048,"sku":"TCEMVS-0250LFC","price":1050.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-platinum-500l-twin-coil-solar-cylinder-standard-c-tcemvs-0500lfc-2732368.jpg?v=1780683084","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-250l-twin-coil-solar-cylinder-standard-c","provider":"Getplumb","version":"1.0","type":"link"}