{"product_id":"joule-cyclone-platinum-250l-direct-smart-standard-c-unvented-cylinder","title":"Joule Cyclone Platinum 250L Direct Smart Standard C Unvented Cylinder - TCEMVD-0250LFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 250L Direct Smart Standard C Unvented Cylinder (TCEMVD-0250LFC) is a high-capacity direct unvented hot water cylinder engineered for reliable mains-pressure supply in larger homes and light commercial settings. Constructed from LDX 2101 stainless steel with a coated mild steel outer casing and dense PU foam insulation, it delivers efficient heat retention and fast recovery. Ideal where sustained hot-water demand and long-term durability are required, it includes a 25-year warranty for added confidence.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e250 L actual capacity for larger households or light-commercial use\u003c\/li\u003e\n\u003cli\u003eDirect unvented design compatible with mains-pressure systems\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for corrosion resistance and longevity\u003c\/li\u003e\n\u003cli\u003eOuter casing: coated mild steel for protection and a clean finish\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation to reduce heat loss (Heat loss: 2.14 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eTwo immersion heaters; immersion spec: 3 kW @ 230 V for rapid recovery\u003c\/li\u003e\n\u003cli\u003eMaximum mains water pressure: 10 bar; operating pressure: 7 bar\u003c\/li\u003e\n\u003cli\u003eSafety temperature up to 90 °C with dual-stat control (65 °C label on similar models)\u003c\/li\u003e\n\u003cli\u003eTested to BS EN 12897:2016 standard\u003c\/li\u003e\n\u003cli\u003e25-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarger residential homes with multiple bathrooms or high hot-water demand\u003c\/li\u003e\n\u003cli\u003eSmall commercial properties, guest houses, and staff facilities\u003c\/li\u003e\n\u003cli\u003eRenovation or new-build projects requiring a high-capacity, mains-pressure cylinder\u003c\/li\u003e\n\u003cli\u003eInstallations where low heat loss and long service life are priorities\u003c\/li\u003e\n\u003cli\u003eApplications specified to meet British standards (BS EN 12897:2016)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCEMVD-0250LFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eDIRECT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eDirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (t \u0026amp; p) (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e2.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e25Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069260751184,"sku":"TCEMVD-0250LFC","price":644.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-direct-unvented-300l-cylinder-tcemvd-0300nfc-4716530.jpg?v=1780480659","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-250l-direct-smart-standard-c-unvented-cylinder","provider":"Getplumb","version":"1.0","type":"link"}