{"product_id":"joule-cyclone-platinum-250l-direct-smart-short-c-unvented-cylinder-tcemvd-0250nfc","title":"Joule Cyclone Platinum 250L Direct Smart Short C Unvented Cylinder - TCEMVD-0250NFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 250L Direct Smart Short C Unvented Cylinder (TCEMVD-0250NFC) is a high-capacity, compact unvented hot water cylinder designed to deliver reliable mains-pressure hot water for larger homes and light-commercial sites. Built from LDX 2101 stainless steel with a coated mild-steel outer casing and dense PU foam insulation, it offers strong corrosion resistance, efficient heat retention and fast recovery. Its shorter footprint makes it ideal where installation space is limited but large-volume hot water is required, and it is backed by a 25-year warranty for long-term confidence.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250 L actual capacity for high hot-water demand\u003c\/li\u003e\n\u003cli\u003eShort\/cabinet-friendly form factor for tighter plant rooms or cupboards\u003c\/li\u003e\n\u003cli\u003eDirect unvented design for compatible mains-pressure systems\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for durability and corrosion resistance\u003c\/li\u003e\n\u003cli\u003eOuter casing: coated mild steel for protection and a neat finish\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation for reduced heat loss (2.09 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eTwo immersion heaters; immersion spec: 3 kW @ 230 V for rapid recovery\u003c\/li\u003e\n\u003cli\u003eMaximum mains water pressure: 10 bar; operating pressure: 7 bar\u003c\/li\u003e\n\u003cli\u003eSafety temperature up to 90 °C\u003c\/li\u003e\n\u003cli\u003eTested to BS EN 12897:2016 standard\u003c\/li\u003e\n\u003cli\u003e25-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLarger residential homes with multiple bathrooms or high hot-water usage\u003c\/li\u003e\n\u003cli\u003eSmall commercial properties, guest houses or staff facilities\u003c\/li\u003e\n\u003cli\u003eRenovations or retrofits where vertical space is limited but capacity is needed\u003c\/li\u003e\n\u003cli\u003eNew-build projects specifying mains-pressure, high-capacity cylinders\u003c\/li\u003e\n\u003cli\u003eInstallations requiring low heat loss and long service life\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCEMVD-0250NFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eDIRECT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eDirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (t \u0026amp; p) (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e2.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e25Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069260783952,"sku":"TCEMVD-0250NFC","price":644.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-direct-unvented-300l-cylinder-tcemvd-0300nfc-4716530.jpg?v=1780480659","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-250l-direct-smart-short-c-unvented-cylinder-tcemvd-0250nfc","provider":"Getplumb","version":"1.0","type":"link"}