{"product_id":"joule-cyclone-platinum-200l-indirect-horizontal-standard-c-unvented-cylinder","title":"Joule Cyclone Platinum 200L Indirect Horizontal Standard C Unvented Cylinder - TCIMHI-0200NFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 200L Indirect Horizontal Standard C Unvented Cylinder (TCIMHI-0200NFC) is a high-quality horizontal indirect cylinder designed to provide reliable mains-pressure hot water when heated from a boiler, heat pump or solar thermal primary. Built from LDX 2101 stainless steel with a coated mild-steel outer casing and dense PU foam insulation, it offers strong corrosion resistance, low standby heat loss and consistent performance. Suited to homes or light-commercial installs with limited vertical space, it delivers efficient heat transfer and dependable service backed by tested standards.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eActual capacity: 200 L for substantial hot-water storage\u003c\/li\u003e\n\u003cli\u003eIndirect unvented design for use with boilers, heat pumps or solar thermal systems\u003c\/li\u003e\n\u003cli\u003eHorizontal orientation for under-bench or plant-room installations\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for corrosion resistance and longevity\u003c\/li\u003e\n\u003cli\u003eOuter casing: coated mild steel for protection and tidy appearance\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation to reduce heat loss (Heat loss: 2.14 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eSingle 316L stainless-steel coil (20 kW) for efficient primary-to-domestic heat transfer\u003c\/li\u003e\n\u003cli\u003eTwo immersion provisions; immersion spec: 3 kW @ 230 V for auxiliary heating\u003c\/li\u003e\n\u003cli\u003eCoil max primary pressure: 3.5 bar; coil resistance: 45 bar\u003c\/li\u003e\n\u003cli\u003eMax mains water pressure: 10 bar; operating pressure: 7 bar; safety valve temp: 90 °C\u003c\/li\u003e\n\u003cli\u003eTested to BS EN 12897:2016\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential homes, flats or apartments needing a compact horizontal cylinder with good storage capacity\u003c\/li\u003e\n\u003cli\u003eInstallations heated by central boilers, heat pumps or solar thermal loops\u003c\/li\u003e\n\u003cli\u003eRenovation or retrofit projects with limited vertical clearance or under‑bench space\u003c\/li\u003e\n\u003cli\u003eSmall commercial properties or staff facilities requiring reliable indirect hot-water supply\u003c\/li\u003e\n\u003cli\u003eSystems where efficient heat exchange and stainless-steel durability are priorities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCIMHI-0200NFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e196 (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eINDIRECT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eIndirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo heat exchangers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 max primary pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp (°C)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety valve temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e2.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e1Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069260947792,"sku":"TCIMHI-0200NFC","price":1219.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-platinum-300l-indirect-horizontal-standard-c-unvented-cylinder-tcimhi-0300nfc-4310647.jpg?v=1780480659","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-200l-indirect-horizontal-standard-c-unvented-cylinder","provider":"Getplumb","version":"1.0","type":"link"}