{"product_id":"joule-cyclone-platinum-200-litre-indirect-slimline-unvented-cylinder","title":"Joule Cyclone Platinum 200 Litre Indirect Slimline Unvented Cylinder - TCEMVI-0200SFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 200 Litre Indirect Slimline Unvented Cylinder (TCEMVI-0200SFC) is a compact, high-capacity indirect hot‑water cylinder designed for installations with limited space. Engineered from LDX 2101 stainless steel with a coated mild‑steel outer casing and dense PU foam insulation, it delivers reliable mains‑pressure domestic hot water when heated by a boiler, heat pump or solar thermal primary. The slimline footprint, efficient heat exchange and low standby losses make it suitable for small-to-medium homes and tight plant rooms.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e195 L actual capacity in a slimline vertical footprint\u003c\/li\u003e\n\u003cli\u003eIndirect unvented design for use with boilers, heat pumps or solar thermal systems\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for corrosion resistance and longevity\u003c\/li\u003e\n\u003cli\u003eCoil material: 316L stainless steel for efficient, durable heat transfer\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation to minimise standby heat loss (2.02 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eSingle immersion provision (3 kW @ 230 V) for auxiliary electric heating\u003c\/li\u003e\n\u003cli\u003eCoil rating: 22.41 kW with 0.65 m² surface area for fast primary-to-domestic transfer\u003c\/li\u003e\n\u003cli\u003eMax mains water pressure: 10 bar; operating pressure: 7 bar; safety valve temp: 90 °C\u003c\/li\u003e\n\u003cli\u003eTested to BS EN 12897:2016\u003c\/li\u003e\n\u003cli\u003e1-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmall to medium residential homes, flats or apartments needing significant hot‑water storage in a narrow plant room\u003c\/li\u003e\n\u003cli\u003eUnder‑bench cupboards or tight utility spaces where a slimline cylinder is required\u003c\/li\u003e\n\u003cli\u003eSystems heated by a boiler, heat pump or solar thermal loop (indirect primary)\u003c\/li\u003e\n\u003cli\u003eRenovation and retrofit projects with limited space but high hot‑water demand\u003c\/li\u003e\n\u003cli\u003eInstallations prioritising stainless‑steel durability and efficient heat exchange\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCEMVI-0200SFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eINDIRECT SLIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eIndirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo heat exchangers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e22.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 max primary pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp (°C)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety valve temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e2.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e1Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069261144400,"sku":"TCEMVI-0200SFC","price":865.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-standard-in-direct-short-unvented-cylinder-250-litre-stainless-steel-6322821.jpg?v=1780567571","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-200-litre-indirect-slimline-unvented-cylinder","provider":"Getplumb","version":"1.0","type":"link"}