{"product_id":"joule-cyclone-platinum-170l-indirect-horizontal-standard-c-unvented-cylinder","title":"Joule Cyclone Platinum 170L Indirect Horizontal Standard C Unvented Cylinder - TCIMHI-0170LFC","description":"\u003cp\u003eThe Joule Cyclone Platinum 170L Indirect Horizontal Standard C Unvented Cylinder (TCIMHI-0170LFC) is a compact horizontal indirect cylinder engineered to deliver reliable hot water when heated via a primary boiler, heat pump or solar thermal loop. Constructed from LDX 2101 stainless steel with a coated mild‑steel outer casing and dense PU foam insulation, it combines corrosion resistance, efficient heat retention and consistent heat transfer. Suited to homes or apartments with limited vertical space, it offers dependable performance and straightforward installation for indirect heating systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eActual capacity: 168 L in a horizontal, space-saving form factor\u003c\/li\u003e\n\u003cli\u003eIndirect unvented design for use with boilers, heat pumps or solar thermal systems\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for long-term corrosion resistance\u003c\/li\u003e\n\u003cli\u003eOuter casing: coated mild steel for a neat, protective finish\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation to minimise heat loss (Heat loss: 1.39 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eSingle 316L stainless-steel coil (Coil rating: 20 kW; surface area: 0.57 m²) for efficient heat transfer\u003c\/li\u003e\n\u003cli\u003eOne immersion heater provision (3 kW @ 230 V) for auxiliary heating\u003c\/li\u003e\n\u003cli\u003eCoil maximum primary pressure: 3.5 bar; coil resistance listed (0.05 \/ 45 bar entries reflect coil data)\u003c\/li\u003e\n\u003cli\u003eMaximum mains water pressure: 10 bar; operating pressure: 7 bar; safety valve temp: 90 °C\u003c\/li\u003e\n\u003cli\u003eTested to BS EN 12897:2016 and supplied with a 1-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmall to medium residential homes, flats or apartments with limited vertical space\u003c\/li\u003e\n\u003cli\u003eInstallations heated via central boiler, heat pump or solar thermal primary loop\u003c\/li\u003e\n\u003cli\u003eUnder‑bench, cupboard or plant‑room installations where a horizontal cylinder fits best\u003c\/li\u003e\n\u003cli\u003eRenovation and retrofit projects requiring a compact, stainless‑steel indirect cylinder\u003c\/li\u003e\n\u003cli\u003eSystems prioritising efficient heat exchange and low standby losses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCIMHI-0170LFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e167 (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eHORIZONTAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eIndirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo heat exchangers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 max primary pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 2 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp (°C)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety valve temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e1.39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested to standard\u003c\/td\u003e\n\u003ctd\u003eBS EN 12897:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e1Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069260915024,"sku":"TCIMHI-0170LFC","price":1085.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-platinum-300l-indirect-horizontal-standard-c-unvented-cylinder-tcimhi-0300nfc-4310647.jpg?v=1780480659","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-170l-indirect-horizontal-standard-c-unvented-cylinder","provider":"Getplumb","version":"1.0","type":"link"}