{"product_id":"joule-cyclone-platinum-150-litre-indirect-horizontal-unvented-cylinder","title":"Joule Cyclone Platinum 150 Litre Indirect Horizontal Unvented Cylinder (TCIMHI-0150LFB)","description":"\u003cp\u003eThe Joule Cyclone Platinum 150 Litre Indirect Horizontal Unvented Cylinder (TCIMHI-0150LFB) is a compact horizontal hot water cylinder engineered for indirect heating systems (boiler, heat pump or solar thermal). Built from LDX 2101 stainless steel with a coated mild-steel outer casing and dense PU foam insulation, it offers reliable corrosion resistance, efficient heat retention and consistent performance in space‑restricted plant rooms or under-bench installations. Ideal for small homes or apartments, it delivers fast heat transfer and dependable hot water distribution with a straightforward, service-friendly design.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eActual capacity: 148 L — compact horizontal footprint for limited vertical space\u003c\/li\u003e\n\u003cli\u003eIndirect unvented design for use with boilers, heat pumps or solar thermal systems\u003c\/li\u003e\n\u003cli\u003eHorizontal orientation suited to under-bench or plant-room installations\u003c\/li\u003e\n\u003cli\u003eCylinder material: LDX 2101 stainless steel for long-lasting corrosion resistance\u003c\/li\u003e\n\u003cli\u003eOuter casing: coated mild steel for protection and clean appearance\u003c\/li\u003e\n\u003cli\u003eDense PU foam insulation to minimise heat loss (Heat loss: 1.32 kWh\/24h)\u003c\/li\u003e\n\u003cli\u003eSingle 316L stainless-steel coil for efficient heat exchange (Coil rating: 20 kW)\u003c\/li\u003e\n\u003cli\u003eOne immersion heater provision (3 kW @ 230 V) for auxiliary heating\u003c\/li\u003e\n\u003cli\u003eCoil\/resistance specification supports reliable primary loop performance (surface area 0.57 m²; coil resistance 45 bar)\u003c\/li\u003e\n\u003cli\u003eMax mains water pressure: 10 bar; operating pressure: 7 bar; safety valve temp: 90 °C\u003c\/li\u003e\n\u003cli\u003eLightweight empty unit (34 kg) for easier handling during installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmall residential homes, flats or apartments needing a compact hot-water cylinder\u003c\/li\u003e\n\u003cli\u003eInstallations using a boiler, heat pump or solar thermal primary for indirect heating\u003c\/li\u003e\n\u003cli\u003eRenovations or retrofits where vertical clearance is limited and a horizontal cylinder is preferred\u003c\/li\u003e\n\u003cli\u003eUnder-bench plant rooms, cupboards or compact utility spaces\u003c\/li\u003e\n\u003cli\u003eProjects requiring a stainless-steel heat exchanger for durability and rapid heat delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTCIMHI-0150LFB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCYCLONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (L)\u003c\/td\u003e\n\u003ctd\u003e147 (rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActual capacity (Ltr)\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Group Code\u003c\/td\u003e\n\u003ctd\u003eHORIZONTAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Category Code\u003c\/td\u003e\n\u003ctd\u003eStainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eERP Type\u003c\/td\u003e\n\u003ctd\u003eIndirectUnvented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder material\u003c\/td\u003e\n\u003ctd\u003eLDX 2101 (stainless steel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter casing\u003c\/td\u003e\n\u003ctd\u003eCoated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal insulation\u003c\/td\u003e\n\u003ctd\u003eDense PU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam thickness (mm)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo immersions\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion spec\u003c\/td\u003e\n\u003ctd\u003e3 kW @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo heat exchangers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 rating (kW)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 surface area (m²)\u003c\/td\u003e\n\u003ctd\u003e0.57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil 1 resistance (Bar)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax mains water pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp (°C)\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety valve temp (°C)\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight empty (kg)\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight full (kg)\u003c\/td\u003e\n\u003ctd\u003e184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat loss (kWh\/24h)\u003c\/td\u003e\n\u003ctd\u003e1.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty terms (years)\u003c\/td\u003e\n\u003ctd\u003e1Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Joule","offers":[{"title":"Default Title","offer_id":53069260882256,"sku":"TCIMHI-0150LFB","price":1078.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/joule-cyclone-platinum-300l-indirect-horizontal-standard-c-unvented-cylinder-tcimhi-0300nfc-4310647.jpg?v=1780480659","url":"https:\/\/getplumb.co.uk\/products\/joule-cyclone-platinum-150-litre-indirect-horizontal-unvented-cylinder","provider":"Getplumb","version":"1.0","type":"link"}