{"product_id":"honeywell-v4044c-1288-22mm-3-port-motorised-diverter-valve-v4044c1288-u","title":"Honeywell V4044C 1288 22mm 3-Port Motorised Diverter Valve - V4044C1288\/U","description":"\u003cdiv style=\"font-family: Arial, sans-serif; color: #1e293b; font-size: 16px; line-height: 1.7;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell Home V4044C 22mm 3-Port Motorised Diverter Valve (V4044C1288\/U)\u003c\/strong\u003e is designed to control the flow of water between the heating and hot water circuits in domestic fully pumped central heating systems. It is intended for use in a \u003cstrong\u003eSundial W Plan hot water priority system\u003c\/strong\u003e, allowing water flow to be directed to one zone at a time.\u003c\/p\u003e\n\u003cp\u003eFeaturing two-position operation and a spring return mechanism, this 22mm motorised valve provides electrical output to the boiler or pump. Its replaceable powerhead can be changed without draining down the system, helping simplify maintenance.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px; margin: 18px 0;\"\u003e\n\u003cspan style=\"background: #f1f5f9; padding: 6px 12px; border-radius: 20px;\"\u003e22mm Compression\u003c\/span\u003e \u003cspan style=\"background: #f1f5f9; padding: 6px 12px; border-radius: 20px;\"\u003e3-Port Diverter Valve\u003c\/span\u003e \u003cspan style=\"background: #f1f5f9; padding: 6px 12px; border-radius: 20px;\"\u003e230V AC Supply\u003c\/span\u003e \u003cspan style=\"background: #f1f5f9; padding: 6px 12px; border-radius: 20px;\"\u003e1-Year Warranty\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003eKey Features\u003c\/h3\u003e\n\u003ch4\u003e1. 22mm Compression Connections\u003c\/h4\u003e\n\u003cp\u003eFeatures 22mm inlet and outlet connection sizes for compatible domestic central heating pipework.\u003c\/p\u003e\n\u003ch4\u003e2. Three-Port Diverter Valve\u003c\/h4\u003e\n\u003cp\u003eControls water flow between the heating and hot water circuits in a fully pumped central heating system.\u003c\/p\u003e\n\u003ch4\u003e3. Designed for Sundial W Plan Systems\u003c\/h4\u003e\n\u003cp\u003eSuitable for the Sundial W Plan hot water priority arrangement, directing flow to one zone at a time.\u003c\/p\u003e\n\u003ch4\u003e4. Two-Position Spring Return Operation\u003c\/h4\u003e\n\u003cp\u003eUses two-position operation with a spring return action to control the direction of water flow.\u003c\/p\u003e\n\u003ch4\u003e5. Replaceable Powerhead\u003c\/h4\u003e\n\u003cp\u003eThe powerhead can be replaced without draining down the heating system, making servicing more convenient.\u003c\/p\u003e\n\u003ch4\u003e6. Quiet and Low-Energy Operation\u003c\/h4\u003e\n\u003cp\u003eDesigned for quiet operation with minimal power consumption. It includes a manual lever for filling and draining down.\u003c\/p\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 12px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell Home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eModel \/ Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eV4044C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eV4044C1288\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eValve Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eMotorised Diverter Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eNumber of Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eInlet Connection Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e22mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eOutlet Connection Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e22mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTwo Position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eReturn Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSpring Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eBrass (supplier specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eBronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e112mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e5°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eMaximum Close-Off Differential Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.69 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f1f5f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e8.6 bar (supplier specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the Honeywell Home V4044C valve used for?\u003c\/h4\u003e\n\u003cp\u003eIt controls the flow of water between the heating and hot water circuits in domestic fully pumped central heating systems.\u003c\/p\u003e\n\u003ch4\u003eWhich heating system is the V4044C designed for?\u003c\/h4\u003e\n\u003cp\u003eIt is designed for use in the Sundial W Plan hot water priority system.\u003c\/p\u003e\n\u003ch4\u003eWhat size connections does this valve have?\u003c\/h4\u003e\n\u003cp\u003eThis model has 22mm compression inlet and outlet connections.\u003c\/p\u003e\n\u003ch4\u003eCan the powerhead be replaced without draining the system?\u003c\/h4\u003e\n\u003cp\u003eYes. The powerhead is replaceable without draining down the heating system.\u003c\/p\u003e\n\u003ch4\u003eWhat power supply does the valve require?\u003c\/h4\u003e\n\u003cp\u003eThe supplied specification states that it requires a 230V AC power supply.\u003c\/p\u003e\n\u003ch3 style=\"color: #1e3a5f;\"\u003eOrder Honeywell Home Heating Controls from GetPlumb\u003c\/h3\u003e\n\u003cp\u003eShop the Honeywell Home V4044C 22mm 3-Port Motorised Diverter Valve at GetPlumb. Designed for compatible W Plan heating systems, with a replaceable powerhead and spring return operation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53904740680016,"sku":"V4044C1288\/U","price":128.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5268\/4624\/files\/honeywell-v4044c-1288-22mm-3-port-motorised-diverter-valve-v4044c1288u-4605812.jpg?v=1793614935","url":"https:\/\/getplumb.co.uk\/it\/products\/honeywell-v4044c-1288-22mm-3-port-motorised-diverter-valve-v4044c1288-u","provider":"Getplumb","version":"1.0","type":"link"}